Frequency converters

Catalog
Sort By: all in stock




product

SIEMENS fixed-mounted circuit breaker

3WL1110-2..34-.... product-settings

fixed-mounted circuit breaker 3-pole, size I, IEC In=1000A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole

under the order
product

SIEMENS circuit breaker 3VA5

3VA5225-7ED31-0AA0

circuit breaker 3VA5 UL frame 250 breaking capacity class C 100kA @ 480V 3-pole, line protection TM210, FTFM, In=250A overload protection Ir=250A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5217-7ED31-0AA0

circuit breaker 3VA5 UL frame 250 breaking capacity class C 100kA @ 480V 3-pole, line protection TM210, FTFM, In=175A overload protection Ir=175A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5212-7ED31-0AA0

circuit breaker 3VA5 UL frame 250 breaking capacity class C 100kA @ 480V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5210-7ED31-0AA0

circuit breaker 3VA5 UL frame 250 breaking capacity class C 100kA @ 480V 3-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5190-6ED31-0AA0

circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, line protection TM210, FTFM, In=90A overload protection Ir=90A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5160-6ED31-0AA0

circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, line protection TM210, FTFM, In=60A overload protection Ir=60A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5140-6ED31-0AA0

circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, line protection TM210, FTFM, In=40A overload protection Ir=40A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5135-6ED31-0AA0

circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, line protection TM210, FTFM, In=35A overload protection Ir=35A fixed short-circuit protection Ii=10 x In without connection

under the order
product

SIEMENS circuit breaker 3VA5

3VA5120-6ED31-0AA0

circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, line protection TM210, FTFM, In=20A overload protection Ir=20A fixed short-circuit protection Ii=15 x In without connection

under the order




Partners

Call back